DRV bis 100 L/Min.

Eaton Model 1PA100
Einschraubbohrung A880

Eaton Integrated - 1PA100 - Pressure reducing valve - pilot operated
sliding spool type

Application
To maintain a constant downstream pressure lower than the inlet pressure. Ideal for use in two pressure systems or to protect low pressure actuators such as brake cylinders.

Features
Internal parts hardened, match ground and honed to give long, trouble-free life. Pilot style design allows for high flows and accurate performance.

Operation
This valve is normally open, allowing oil from the inlet to pass through to the regulated port of the cartridge. When the regulated pressure reaches the valve setting, the pilot section opens causing a pressure imbalance across the main spool which moves, throttling the inlet flow, preventing any further pressure rise in the regulated line.

Adjustment Means
P =
Leakproof Screw Adjustment

Varianten

Artikel-Nr. Variante Model Code max. Betriebsdruck [bar] max. Durchfluss [L/Min] Einschraubbohrung Einstellbereich [bar] Dichtung Standard-Einstellung [bar]
540 125 510 1 1PA100-P-20-S 210 100 A880 15-210 Nitrile 100

Download:

Datenblatt Eaton 1PA100

Eaton 1PA100 - Druckregelventil

Download (55.35KB)